Products

DIGMAM 14

Test Phantom for constancy test according to DIN 6868/14 of digital mammography equipment.


DIGMAM 14 – retrofil set

Retrofit kit to PAS 1054-testphantom for constancy test according to DIN 6868/14 of digital mammography equipment.


Fluorad 150

PDF for more information

Testphantom for acceptance testing of X-ray exposure and fluoroscopy equipment (acc. DIN 6868/150).

With the “Fluorad 150” testphantom it is possible to measure the following parameters:

– Dynamic Range
– Contrast Resolution
– Spatial Resolution
– Beam Quality
– Homogeneity

Dimensions: 300mm*300mm*18.5mm.

The copper plate within the details is bedded in acrylglass plates.
The acrylglass is white, so that the light beam can be better seen under spotlight conditions.
The structures are painted on booth sides of the testphantom.


RCmin

PDF for more information

Illuminance Meter for testing the illuminance of diagnostic environments according to the new DIN 6868-157
By using the RCmin, you can extend the prescribed time interval for constancy testing of image display devices with regard to the key parameters “veiling luminance” and “maximum contrast” to six months.
The RCmin is a valuable tool for use wherever constant illuminance is important.

• with USB Interface


CD Gam 1

PDF for more information

For immediate detection of ionizing (radioactive) radiation via Geiger-Müller-counter.

• easy-to-use measurement device for immediately detecting ionizing radiation (alpha-, beta-, gamma- and X-ray-radiation)
• quickly determine of radiation dose and radiation exposure
• small, lightweigth portable unit
• accustic and visual display
• optical, acoustical and vibration alarm

Fluorad 150

PDF for more information

Testphantom for acceptance testing of X-ray exposure and fluoroscopy equipment (acc. DIN 6868/150).

With the “Fluorad 150” testphantom it is possible to measure the following parameters:

– Dynamic Range
– Contrast Resol.
– Spatial Resolution
– Beam Quality
– Homogeneity

Dimensions: 300mm*300mm*18.5mm.

The copper plate within the details is bedded in acrylglass plates.
The acrylglass is white, so that the light beam can be better seen under spotlight conditions.
The structures are painted on booth sides of the testphantom.


DIGRAD A+K

PDF for more information

Testphantom per German standard (DIN 6868/13) for constancy tests of digital radiography equipment (e.g. storage phosphor or full digital).

With “DIGRAD A+K” you are able to measure all parameters required by above standard:
– dynamic range
– contrast resolution
– homogeneity
– spatial resolution
– position and size of the effective radiation field


Absorption Filter

25 mm aluminum filter w/ insertion frame for mounting near X-Ray tube.
Also available with insertable dose-detector.

Fluorad 150

PDF for more information

Testphantom for acceptance testing of X-ray exposure and fluoroscopy equipment (acc. to DIN 6868/150).

With the “Fluorad 150” testphantom it is possible to measure the following parameters:

– Dynamic Range
– Contrast Resol.
– Spatial Resolution
– Beam Quality
– Homogeneity

Dimensions: 300mm*300mm*18.5mm

The copper plate within the details is bedded in acrylglass plates.
The acrylglass is white, so that the light beam can be better seen under spotlight conditions.
The structures are painted on booth sides of the testphantom.


Fluorad A+D

PDF for more information

Testphantom for constancy tests of digital and analogue fluoroscopy equipment (according to DIN 6868/4:2007).

With the “Fluorad A+D” testphantom it is possible to measure the following parameters:

– Dynamic Range
– Contrast Resolution
– Spatial Resolution
– Beam Quality
– Homogeneity

Dimensions:
“Fluorad 30 A+D”: 300mm*300mm*18.5mm
Fluorad 20 A+D”: 200mm*200mm*18.5mm

The copper plate within the details is bedded in acrylglass plates. The acrylglass is white, so that the light beam can be better seen under spotlight conditions.


DSA – Testphantom

PDF for more information

A special DSA testphantom system is needed in order to conduct the prescribed acceptance- and constancy-testing of the DSA-specific key parameters of Digital Subtractionangiography equipment in accordance with DIN 6868 Part 150 and Part 4.

The test phantom contains a movable insert with aluminium strips for blood vessel simulation.
This insert is moved via a pneumatic system during the exposure series.


Fluoro Phantom “D”

PDF for more information

To check the digital fluoroscopic techniques.


Sensor in absorption filter

Fits the “ALPHA plus” Dosimeter for the constancy test of all analogue and digital fluoroscopic equipment.

The sensor is located above the patient-equivalent-filter (25mm Al) under the insertion plate.

Energy range: 50kV – 155kV

Effective dose range: 0,1mGy/s – 500mGy/s

DVT 161

PDF for more information

Testphantom for acceptance and constancy testing of 3D function of dental cone-beam computed tomography as per DIN 6868-161 and QS-RL.

Diameter of the slabs: 160mm

Thickness:
2 x 20mm
1 x 50mm
1 x 60mm


DVT 150

PDF for more information

Testphantom for acceptance testing of 3D functions of cone-beam computed tomography in fluoroscopy as per DIN 6868-150.

Dimensions: 120mm*120mm*60mm

Thickness of the slabs::
1 x 10mm
2 x 25mm

CT Phantom

CT-Phantom for CTDI-Measurements on CT-Scanners according to IEC 60601-2-44, IEC 61223-3-5 and IEC 61223-2-6.

Consist of:

1xAdulthead-/childbodyphantom, 16 cm ø, with 5 holes;

1xAdultbody-phantom, 32 cm ø, with 4 holes;

9 plugs;

Thickness: 15 cm

Weight: 14 kg

Delivery with special carrying case.

DIGMAM 162

PDF for more information

Testphantom for acceptance test of digital mammography equipment according to DIN 6868/162.


DIGMAM 14

Testphantom for constancy test according to DIN 6868/14 of digital mammography-equipment.


DIGMAM 14 – retrofit kit

Retrofit kit to PAS1054-Testphantom for constancy test according to DIN 6868/14 of digital mammography-equipment.


Biopsie Phantom-Set

PDF for more information

Testphantom Set for the daily constancy test of digital Mammography Stereotaxie imaging systems (Biopsy).

Consist of:
pehamed test plate KP-MDP and Phantom Holder for Biopsy (011066).

Case included.

For the acceptance tests is the test plate A+KP-MDP required.


Biopsie Phantom-Holder

PDF for more information

Phantom Holder for Biopsy acryl resin plate with cut-out for pehamed Test plate KP-MDP for the daily constancy test of digital Mammography Stereotaxie imaging systems (Biopsy).
Delivery without test plate KP-MDP! Case included.


Phantom DINo 152,7

PDF for more information

Test phantom for monitoring the technical parameters of mammography imaging systems per the requireents of the “European Guidelines for Quality Assurance in MammographyScreening”.


Phantom DIGMAM

PDF for more information

The DIGMAM phantom can be used to perform both the acceptance and the constancy tests of digital mammography exposure units.

The test phantom is equipped with a lead bar resolution pattern with special range (5,6,7,8,10 LP/mm) for digital mammographic X-­ray equipment.


Europhantom MAMMO

PDF for more information

Test phantom for monitoring the technical parameters of mammography imaging systems per the requirements of the “European Guidelines for Quality Assurance in MammographyScreening”.


Resolution Phantom

A supplementary phantom for use with mammography phantoms.
For inspection and analysis of the current radiological image quality of the total mammography system, in addition to the acceptance and constancy tests.

DIRADENT

PDF for more information

Testphantom for acceptance and constancy testing of digital dental X-ray-units per German standards DIN 6868/5 and DIN 6868/151 and international standards IEC 61223-2-7 and IEC 61223-3-4.


DIRADENT – package

PDF for more information

For acceptance and constancy testing of digital X-ray-equipment for Dental per: DIN 6868/151, DIN 6868/5, IEC 61223–3–4 and IEC 61223–2–7.

Package Contents:

– Phantom DIRADENT
– Phantom Holder (System “GENDEX”, or “GENDEX 8000”, or “OP100”, or “SIRONA”)*
– Copper plate Absorption filter 1,8mm Cu
– System Case “Tecno” blue (small)

* optional: additional with Phantom Holder for System “CEPH” and with Copper plate Absorption filter 0,8mm Cu

ALPHA 6868/3

Test phantom for constancy testing in analogue X-ray direct radiography (without fluoroscopy) per “German*DIN*standard” (DIN 6868 Part 3).


ALPHA 6868/3+4

Test phantom for constancy testing in X-ray direct radiography and fluoroscopy per “German*DIN*standard” (DIN 6868 Part 3 and Part 4).


Absorption Filter

25 mm aluminum filter w/ insertion frame for mounting near X-Ray tube.

Also available with integrated dosedetector (compatible with the “ALPHA plus” dosimeter) or insertion slot for “finger”-detector.

ALPHAplus

PDF for more information

Measurement device with LCD, serial interface and plug-in for different detectors.
For the constancy test of all analog and digital X-ray-equipment (directradiography, fluoroscopy techniques, dental-X-ray and mammography).

Display of:
dose,
dose rate and
exposure time.

Note: Unit is delivered without sensor! It must be ordered separately. (See below)


Sensor in absorption filter

Fits the “ALPHAplus” for the constancy test of all analog X-ray equipment and analog and digital fluoroscopic techniques.
Not for digital radiography or mammography X-ray equipment!

The sensor is located above the patient-equivalentfilter (25mm Al) under the insertion plate.

Energy range: 50kV – 155kV

Effective dose range: 0,1mGy/s – 500mGy/s


“Finger”-Sensor

Fits the “ALPHAplus” for the constancy test of digital X-ray-equipment (directradiography and fluoroscopy; not for dental or mammography).

Because of its shape the sensor is suitable for insertion into the patientequivalentfilter for use with near-the-tube measurements as well as an external sensor.

Energy range: 50kV – 155kV

Effective dose range: 0,1mGy/s – 500mGy/s


Mammo-Sensor

Fits the “ALPHAplus” for the constancy test of all analog or digital mammography X-ray equipment.

Energy range: 24kV – 40kV

Effective dose range: 0,1mGy/s – 500mGy/s

CD GAM 1

PDF for more information

Easy-to-use measurement device for detection of ionizing(radioactive)radiation via Geiger-Muller-counter.

• for immediately detecting of ionizing radiation (alpha-, beta-, gamma- and X-ray-radiation)
• quickly determine of radiation dose and radiation exposure
• small, lightweigth portable unit
• accustic and visual display
• optical, acoustical and vibration alarm

RCmin

Illuminance Meter for diagnostic environments according to the german standard DIN 6868-157

By using the RCmin, you can extend the prescribed time interval for constancy testing of image display devices with regard to the key parameters “veiling luminance” and “maximum contrast” to six months.

The RCmin is a valuable tool for use wherever constant illuminance is important.

With USB Interface


CDmon

PDF for more information

Digital Luminance-/Illuminancemeter for the acceptance test and constancy test of viewing boxes and monitors

  • Especially designed for luminance measurements (including the influence of ambient light) of image display devices (monitors, display, screens etc.) according to DIN 6868/157 and of viewing devices according to DIN 6856
  • Display and optical measurement system combined in one compact housing. Measurement of luminance in cd/m² and illuminance in lux with one device
  • Back-light display for good readability in dark rooms
  • USB interface for data transmission to a PC and charging the rechargeable battery

Measurement ranges:
0.01 – 10,000 cd/m²
0.1 – 10,000 lx

PEHAview SCA 157

PDF for more information

Software for the Quality Assurance of Image Display Devices used for diagnostic purposes.

According to the german standard DIN 6868/157, the german “Quality*Assurance*Guidelines”, Ö-Norm ONR 195240, Instructions R-08-06/05/02.Full- or dental version (single solution)

  • Professional (for technicians and small network solutions)
  • Client/Server solutions

KermaX IDP

Dose*Area*Product*Meter
with transparent ionization chamber with integrated electronics and internal LCD display.

The KermaX IDP is intended to be mounted on the face of diagnostic X-ray collimators for measuring dose area product or AEP (Area Exposure Product) during diagnostic radiological examinations.

The KermaX IDP was especially designed for mounting close to the X-ray tube and is inserted into the guide rails of the collimator. The fixation of the chamber may be done by the user.

Delivered with optional choice of insertion frames (176mm or 167 mm) or adapter for additional filters.


KermaX SDP

Dose*Area*Product*Meter with transparent ionization chamber with integrated electronics and external LCD display (single-line).

The external LCD display unit can be installed on the control console and connected to a PC or printer.

See KermaX IDP for other features.


KermaX DDP single

Dose*Area*Product*Meter with transparent ionization chamber with integrated electronics and external LCD display (double-line).

The external LCD display unit can be placed on the control console and connected to a PC or printer.
Two ionization chambers can be connected. If only one ionization chamber is installed, two of the three parameters “dose area product”, “dose area product rate” or “time” can be displayed at the same time.

See KermaX IDP for other features.


KermaX DDP duo

Dose*Area*Product*Meter with two transparent ionization chambers with integrated electronics and external LCD display (double-line).

See KermaX DDP single for other features.

Densonorm 21 ECO

PDF for more information

21 step sensitometer/densitometer with measuring arm integrated in one unit.

For constancy testing of film processing and measurement of test phantom films.


Densonorm 21 E / E-CAL

PDF for more information

21 step sensitometer and densitometer with measuring arm integrated in one unit. For constancy testing of film processing and measurement of test phantom films.

display of LE and LK after measurement of 21 step wedge densities and base+fog.

E-CAL: high precision sensitometer calibrated per DIN 6868/55. Suitable for use for acceptance testing.


Densonorm 21 i / i-CAL

PDF for more information

21 step sensitometer and densitometer with measuring arm and scanner for motorized measurement of 21 step film strips in one unit.

Automatic calculation of speed index, contrast index (according to DIN or ANSI), LE, LK, rel. speed and aver. gradient.

Memory function stores density values for up to 3 film strips.

RS-232 interface for connection to a PC or compatible printer.

i-CAL: high precision sensitometer calibrated per DIN 6868/55. Suitable for use for acceptance testing.

Firmware for asymmetric film types (optional): for motorized measurement of 2 x 21 step wedges of asymmetrical film types followed by automatic calculation of LE and LK, speed index, contrast index (according to DIN or ANSI), rel. speed and average gradient.


Sensi*C / *CAL

PDF for more information

21 step, dual-spectrum, single-side sensitometer for constancy testing of film processing of blue- and green-sensitive films.

*CAL: high precision sensitometer calibrated per DIN 6868/55. Suitable for acceptance testing of film processing.


Densoquick 2 / i LE / TR

PDF for more information

calibratable densitometer for single point measurements of optical densities of transparent films (e.g. X-ray-films).

i LE: with RS-232 interface. Can measure 21 step wedge densities and Dmin for automatic calculation of LE, LK, rel. speed and average gradient.

TR: especially for measurement of dry laser films (also usable for normal films).


Sensi-Dent

Compact dual-spectrum, 5 point pocket sensitometer for constancy testing of dental films.
Also usable for conventional blue- and green-sensitive X-ray films.


Denso-Dent

Pocket densitometer for single point measurements during quality control of dental films and conv. X-ray films.

LED-X

PDF for more information

Darkroom-Safelight for all bluesensitive/orthochromatic films (red light).

For small and mid-sized darkrooms.

Very bright, with energy-saving LEDs.

With brightness control.

Unit works with Power Adapter:
AC 110V-230V / 50-60Hz
DC 12V / 700mA.

Dimensions: 16cm x 11cm x 7cm

With red LEDs and red filter (Polymethylmethacrylat – PMMA)

Spectrum: 640nm

Package “DIGMAM 14”

for constancy testing according to the german standard DIN 6868/14 of digital mammography equipment.


Package “DIGMAM 162”

PDF for more information

for acceptance testing according to the german standard DIN 6868/162 of digital mammography equipment.


Package “FM”

For constancy testing of: Digital X-ray-equipment for Direct Radiography (German standard DIN 6868/13) (image analysis on a monitor)

Package contents:
– DIGRAD Test phantom
– CDmon
– Dosimeter “ALPHAplus”
– “Finger”-Detector
– Absorption filter
– Copper-plate for exposures with 100 kV
– Phantom holder for Bucky wall stand
– Standardized distance plate
– Digital Radiography Forms
– “Markant” Case blue

The package is also available with the light meter CD lux (instead of CDmon) or without a light meter.


Package “GM”

For constancy testing of: Digital X-ray-equipment for Direct Radiography (per German standard DIN 6868/13) and X-ray-equipment for Fluoroscopy (per German standard DIN 6868/4)

Package Contents:
– “DIGRAD” Test phantom
– “FLUORAD 30” Test phantom
– “CDmon”
– Dosimeter “ALPHAplus”
– “Finger”-Detector
– Dose Detector in the Absorption filter
– Absorption filter
– Copper-plate for exposures with 100 kV
– Phantom holder for Bucky wall stand
– Standardized distance plate
– Direct Radiography Forms
– Fluoroscopic Forms
– “Markant” Case blue

The package is also available with the light meter CD lux (instead of CDmon) or without a light meter.


Package “HM”

For constancy testing of: X-ray-equipment for Fluoroscopy (per German standard DIN 6868/4)

Package Contents:
– FLUORAD 30 Test phantom (DIN 6868 / 4)
– CDmon (light intensity measuring device)
– Dosimeter “ALPHAplus” Basic Unit
– Dose Detector in the Absorption filter
– Standardized distance plate
– Fluoroscopic Forms
– “Markant” Case blue

The package is also available with the light meter CD lux (instead of CDmon) or without a light meter.


Package “9” Mammography

For constancy testing of X-ray-equipment for Mammography (per German standard DIN 6868/7)

Package Contents:
– Basic Absorption Plate (40mm PMMA)
– Norm Phantom (DIN 6868/7)
– Add-on Plate 20mm
– Dosimeter “ALPHAplus”
– Mammography-Detector
– Magnifying Glass
– Forms “Mammography”
– System Case


Package “12” EURO-Mammo

For constancy testing of: X-ray-equipment for Mammography according to the requirements of the “European*Guidelines*for*Quality*Assurance in Mammography Screening”

Package contents:
– Euro-Phantom “MAMMO”
– Additional Absorption Plate (20mm PMMA)
– Magnifying Glass (6x)
– Mammography Forms
– System Case


Package Dental DIRADENT

PDF for more information

For acceptance and constancy testing of digital X-ray-equipment for Dental per:
DIN 6868 / Part 151,
DIN 6868 / Part 5,
IEC 61223 – 3 – 4
IEC 61223 – 2 – 7

Package Contents:
– Dental phantom DIRADENT
– Phantom Holder* (System “GENDEX”, or “GENDEX 8000”, or “OP100”, or “SIRONA”)
– Copper plate Absorption filter 1,8mm Cu
– System Case Tecno blue (small)

* optional: additional with Phantom Holder for System “CEPH” and with Copper plate Absorption filter 0,8mm Cu

Cassette Test Grid

For normal X-Ray cassettes
Test grid for testing cassette film-screen contact.

With field (25 mm x 25 mm) to measure the optical density.

Mesh size: 3.15mm
Wire diameter: 0.71mm
Dimensions:420mm*450mm*6mm


Mammo Test Grid

For mammography cassettes
Very fine-mesh test grid especially to test the film-screen contact of mammography-cassettes.

With field (25mm x 25mm) for measure the optical density.

Mesh size: 0.5 mm
Wire diameter: 0.1 mm
Dimensions:240mm*300mm*6mm

Quick-Print “G”

PDF for more information

For Patient*ID*printing on X-ray films in the darkroom.

ID printing with paper strips.

Model “G” with print area as per German standard.

Table mounting or with adapter for light-tight installation in an existing cut-out of a film bin.

Quality Assurance in Radiology

PDF for more information

Broschure for “Quality*Assurance*in*Radiology”.

On 100 pages you can learn the basics about Sensitometry, X-Ray Films, Intensifying Screens and Film Processing.

The main focus from this Paper are the topics Acceptance- and Partial Acceptance Tests, Constancy Tests and Functional Tests.

The paper includes many diagrams, charts and on-road examples for better understanding.

The topics Quality Assurance in Film Viewing Equipment and Image Display Equipment will be explained.

The appending PDF-File shows the first pages of the broschure in german and english language.

Beam Alignment Test tool

Tube of acrylic resin for testing the centering of the X-ray beam.

Dimensions:
Height 164mm
Diameter 70mm


11 Step Alu Stepwedge

11 step aluminumstepwedge for determination of sensitometric curve shape, speed and mid-gradient of X-Ray screen-film systems.

11 steps with a width of 12 mm each.

The height of the first step is 5 mm, following steps are graduated by 3 mm.

Dimensions (HxLxW): 35 mm x 132 mm x 50 mm


21 Step Alu Stepwedge

21 step aluminium wedge for determination of sensitometric curve shape, speed and mid-gradient of X-Ray screen-film systems for medical radiography.

21 steps with a width of 11 mm each.
The graduation is 1,5 mm per step.
Lead numbers mark every step.
Dimensions (HxLxW):
31,5 mm x 230 mm x 112 mm


Mammo Step Wedge

21 step aluminum wedge for determination of sensitometric curve shape, speed and mid-gradient of mammography X-Ray film.

21 steps with a width of 5 mm each.
The steps are graduated by 0,3 mm.
Dimensions (HxLxW):
6,3 mm x 105 mm x 10 mm


Spacer Set

Spacer plate with adjustable legs for positioning DIGRAD test phantom near the X-Ray tube on units without insertion slots (e.g. over-table / under-table tubes, C-arms etc.).


Phantom Holder

Phantom holder for DIGRAD, FLUORAD 150 and ALPHA test phantoms for mounting on Bucky grid wall stands.


Thermometer

Digital mini-thermometer with measurement tip of rust-free, stainless steel to check the developer temperature during quality control of film processing.

Measurement range: -50°C – 150°C
Indication increments: 0.1°C